Le dimanche 18 juin 2006 à 02:20 +0300, Roman Festchook a écrit :
> On Thursday 15 June 2006 00:25, Frédéric Crozat wrote:
> > Hi,
> >
> > I borrowed a Netgear ME 102 AP from a friend of mine and a regression
> > seems to have been introduced between version 1.4.2pre2a and
> > 1.5pre1_FreedomOfUkraine which is still present in 1.5 and 1.5.1pre3,
> > which causes ap-config to return an error when trying to access wireless
> > settings of the AP (other parts seems to work fine).
> Probably AP type detection failed on your AP, try to set AP type manually to 
> ATMEL410 in connect options.

Thanks for your hint..

It didn't work with ATMEL410 but I tried the various MIB extension and I
discovered the problem was caused by usage of GEMTEK MIB extension. If I
set it to "NONE", Wireless configuration page is now displaying
correctly. If you need any network dump to fix autodetection, feel free
to ask.

But I found another bug : wireless configuration stays in polling mode
for configuration retrieval (I'm using french locale) unless I force
POSIX locale using LC_MESSAGES=C.

-- 